Issue:
Warning message received while running Lync Server 2013 Best Practice Analyzer.
Warning message: Best Practices Analyzer cannot
collect all data points from the environment unless Lync Server 2013 backward
compatibility tools are installed on this computer.
Problem Statement: When you run BPA on Lync 2013, you will see
the above warning message. If you have not install all prerequisite then you
will receive warning message. You can eliminate this warning message by
installing WMI Backward Compatibility Package.
Resolution:
Download Lync Server 2013 Best practice analyzer:
There are common prerequisite for Lync
BPA however compatibility package is must to run BPA:
·
Microsoft .NET
Framework 4.5.
·
Lync Server 2013,
Core Components.
·
WMI Backward Compatibility Package. Install ‘OCSWMIBC.msi’
tool.
·
Windows
PowerShell 3.0.
Steps to Install WMI Backward
Compatibility Package.
1. Browse Lync Server 2013 Media and got to following
path.
Path:
\SETUP\AMD64\SETUP\OCSWMIBC.MSI.
2. Double click on OCSWMIBC.MSC and following screen
instruction.
3. Now you can run the BPA and see the result.
Thank